TECHINAL
DATA OF STRONGMAN INCINERATORTYPE
BMW-25
DOUBLE CHAMBER,
CONTROLLED AIR, MANUAL LOADING

1. TECHINAL FEATURES
| Incinerator
Plate Thickness of Primary Chamber |
5 mm. |
| Head
Plate Thickness |
8 mm |
| Chimney
Plate Thickness |
6
mm |
| Thermal
Insulation Thickness of |
50 mm |
| Primary
Chamber & Secondary Chamber |
. |
| Refractory
Thickness of |
100 mm |
| Primary
Chamber & Secondary Chamber |
|
| Chimney
Refractory Lining Thickness |
50 mm |
| Warm-up
Time |
20 min |
2. DIMENSIONS
Primary Chamber
| Inner
Diameter |
700 mm
abt |
| Inner
Length |
1400 mm
abt. |
| Volume |
0.54 m3
abt. |
Secondary Chamber
| Inner
Diameter |
500
mm abt. |
| Inner
Length |
1900
mm abt. |
| Volume |
0.37
m3 abt. |
Chimney
| Inner
Diameter |
250
mm abt. |
| Standard
Height Form Ground Level |
8000
mm abt. |
3. INSTALLED POWERS
| Installed
Electric Power |
kw |
| Voltage |
440/380V/50Hz |
| No
of Burners |
02
Nos |
| Thermal
Capacity Of The Ignition min. |
23
KW |
| Burner
(Primary Chamber) max. |
58
KW |
| Thermal
Capacity Of The min. |
70
KW |
| Secondary
Burner max. |
140KW |
| Fuel
to be used City Gas / Diesel |
|
4. PERFORMANCES
Burning
Capacity With Loader
(Referred to Waste Type C & D
with 2000/2400 Kcal/kg) |
25
kgs/h abt. |
| Working
Temperature of Primary Chamber |
700C-800C |
| Working
Temperature of Secondary Chamber |
1100C-1200C |
| Residence
Time Of The Flue-Gases min. |
2
sec. |
| O2
Rate In The Flue-Gases min. |
6% |
DIMENSIONS
ARE INDICATIVE: STRONGMAN reserve the right to carry out
(also during the supply) the
technical improvements that should be considered suitable.
|