TECHINAL
DATA OF STRONGMAN INCINERATOR
TYPE
BMW-300
OUBLE CHAMBER,
CONTROLLED AIR, AUTO LOADING
1. TECHINAL FEATURES
| Incinerator
Plate Thickness of Primary Chamber |
10 mm. |
| Head Plate
Thickness |
12 mm |
| Chimney
Plate Thickness |
6 mm |
| Thermal
Insulation Thickness of |
50 mm |
| Primary
Chamber & Secondary Chamber |
100 mm |
| Refractory
Thickness of |
|
| Primary
Chamber & Secondary Chamber |
100 mm |
| Chimney
Refractory Lining Thickness |
|
| Warm-up Time |
20 min |
2. DIMENSIONS
Primary Chamber
| Inner
Diameter |
1500 mm
abt. |
| Inner
Length |
2500 mm
abt. |
| Volume |
4.40 m3
abt. |
Secondary Chamber
| Inner
Diameter |
1000
mm abt. |
| Inner
Length |
4000
mm abt. |
| Volume |
3.14
m3 abt. |
Chimney
| Inner Diameter
. |
450 mm abt |
| Standard
Height Form Ground Level |
8000 mm abt. |
3. INSTALLED POWERS
| Installed Electric Power |
kw |
| Voltage |
440/380V/50Hz |
| No of Burners |
03 Nos |
| Thermal Capacity Of The
Ignition min. |
150KW |
| Burner (Primary Chamber)
max. |
348KW |
| Thermal Capacity Of The
min |
232KW |
| Secondary Burner
max |
522KW |
| Fuel to be used City Gas /
Diesel |
|
4. PERFORMANCES
|
Burning Capacity With
Loader 300 kgs/hr abt.
(Referred to Waste Type C & D with 2000/2400 Kcal/kg)
|
|
| Working Temperature of
Primary Chamber |
700C-800C |
| Working Temperature of
Secondary Chamber |
1100C-1200C |
| Residence Time Of The
Flue-Gases min. |
2 sec. |
| O2
Rate In The Flue-Gases min.
|
6%
|